Event

Well come to PTEL!....

Dual Medium Intensity Aviation Obstruction Light Nanhua LM212

Applications:  Applied to iron towers(electicity,telecom, microwave, etc), chimneys(heat-engine plant, coking plant,chemical plant), high buildings, large-scale bridge.large-scale port machinery,large engineer machinery and wind turbines which need the warning for aircraft machines.

LM212 Medium Intensity Dual Aviation Light newly development base on latest LED technology, which installation basement design as flange considering actual application. 
The enclosure of LM201 is made of die casting aluminum with powder coated finish, light weight, waterproof, shockproof and corrosion resistant. Self-contained wiring compartment, ease of mount.

Specifications

Description Parameter
Standard Compliant to the ICAO(Aerodromes Annex 14) and FAA-L864
Light source LED
LED color Aviation red
Operating voltage AC220V/DC48V/DC24V (can be customized)
Power consumption 30W(Steady)
Flashing rate 30 times/min(default), other flashing rate available
Flashing duration 150±20ms
Intensity 2000±25﹪cd
Working  type Bottom light working,top light is spare
Led power consumption 30W
On/off level 50Lux
Vertical degree 3°Min
Horizontal degree 360°
Operating temperature -40˚C ~ +70˚C
IP Protection IP65
Relative humidity 10% ~ 95% (no condensing)
Material Base:Die casting aluminum,  housing: PC   Reflector: ABS   with vacuum coating
Weight 5.5kg

Functions & Features

  • Based on LED technology and meets optics standard
  • Built in LED protective circuit, stability and cost savings
  • Resistant to Shock and Vibrations
  • Corrosion Resistant Lamp& Housing
  • Combustibility rating: UL94-V0。
  • When and if the bottom LEDs fails, it will switch on the top LED automatically, and give an alarm

Installation and operation

  • Install the light on a smooth surface, with enough mechanical strength; if there is no installation surface, we can customize the mounting bracket as requested.
  • When install the light, do not install the photocell towards the light beam around, and also ensure the photocell is not covered by something.
  • Verify whether the supply voltage complied with the rated voltage of the light
  • Open the nameplate cover, connect power cable and earth wire to corresponding terminals and then remount the cover.
  • Power on after verification of connection, the service light will light up

Notice

  • Temperature rise inside the control box is normal phenomenon
  • This product is a sealed structure; Should not be tampered with by anyone other than registered installer
  • Please do not open any components inside by yourself